This depends if you intend to use the inductive proximity sensors supplied with this device. The service temperature limit of cylinder assembly with supplied inductive proximity sensors used is 176°F (80°C). If external limit switches are used, then the service temperature limit of cylinder assembly alone is 356°F (180°C). But, you must check the service temperature limit of whatever limit switches you choose to use as these may have a lower service temperature limit than the cylinder assembly.
PLEASE NOTE: It is important to always sense when the sliding core is in its full forward and fully retracted positions. If this is not done, there is a risk of opening the mold before the core is fully retracted, or attempting to inject into the mold before the core is fully forward and locked.